Installation instructions for PL500 Connections
and mounting
The
table below details the function of each connection:
Normal
Operation The
PL500 has two modes of operation: Toggle or Pulse. When a valid tag is
presented to the reader the relay and LEDs will operate as follows: Toggle
Mode This
mode is typically required for setting and unsetting an intruder alarm system.
On power-up the YELLOW and RED leds will be on and the relay will be OFF (NC
shorted to COM). On presenting a valid tag to the reader, the relay will
switch ON (NO shorted to COM), the GREEN led will turn on and the RED led will
turn off. The next time a valid tag is presented to the reader, the relay
will switch OFF, the RED led will turn on and the GREEN led will turn off.
The next time a valid tag is presented, the relay will switch on again, and so
on. Pulse
Mode This
mode is typically required in access control applications. On power-up the
YELLOW led will be on and the relay will be off (NC shorted to COM). When
a valid tag is read the relay will operate for the programmed Relay Pulse time
(between 1 and 60 seconds). While the relay is on, the GREEN led will be
on. When the relay switches off the GREEN led will turn off again. An
invalid tag will cause the RED led to come on for 2 seconds. Programming The
Master Tag is the first tag presented to the PL500 when it is in the Add Master
state. All programming is done by using this Master Tag. To
select a program function: Make
successive reads of the Master Tag (each read must be no more than 2 seconds
apart). Each
read of the Master Tag sets the PL500 to a new programming function. Add
Master Tag The
first time the reader is powered up it will be in the Add Master Tag state.
This state is indicated by all leds flashing in sync. The Master tag is
the first tag presented to the PL500 when it is in the Add Master Tag state. On
accepting the master tag the PL500 will pulse the GREEN led for 3 seconds and
then go into normal mode (Relay off, YELLOW led on). The Master tag is
required to program the PL500. Add
Tags To
select this function: 1.
Read the Master Tag once. 2.
The GREEN led will light. 3.
Wait for the GREEN led to start flashing. The
PL500 is now in the ADD state. In this state every tag that is presented
to the reader will be stored in the system memory. A maximum of 500 tags
may be stored. Tags can also be added by using the Tag Simulator. Once all
the required tags have been presented, read the Master Tag to return to the
normal mode. Delete
Tags To
remove a tag from the system, that tag must be available or the Tag Simulator
must be used. If these are not available, the system memory must be cleared and
all valid tags re-added. To
select this function: 1.
Read the Master Tag twice with a time between reads of less than 2 seconds. 2.
The RED led will light. 3.
Wait for the RED led to start flashing. The
PL500 is now in the DELETE state. In
this state every tag that is presented to the reader will be deleted from the
system memory. Tags can also be deleted by using the optional Tag Simulator.
Once the tag or a group of tags have been deleted, read the Master Tag to return
to the normal mode. Clear
Memory To
delete all the tags from the memory including the Master Tag and Strike time,
place the unit in the CLEAR MEMORY state. 1.
Read the Master Tag three times with a time between reads of less than 2
seconds. 2.
The GREEN and RED leds will light. 3.
Wait for the GREEN and RED leds to start flashing. The
PL500 is now in the CLEAR MEMORY state. Now present any tag except the Master
Tag to the reader and all memory will be cleared. Alternatively, read the Master
Tag to abort this function. Once
the memory is cleared all leds will flash to indicate that the memory is empty
and the reader will be in the Add Master Tag state. Time
Adjust This
function sets the relay operating time when a valid card is read or the exit
push button is pressed. To
select this function: 1.
Read the Master Tag 4 times with a time between reads of less than 2 seconds. 2.
All the leds will go off. 3.
Wait for the YELLOW led to start blinking (0.25 seconds on, 0.75seconds off).
The PL500 is now in the TIME ADJUST state and each blink of the leds equates to
1 second of relay operation time. When the correct time has passed present
the Master Tag to stop the blinking. The relay time will be stored in
memory and the reader will return to normal mode. The maximum relay pulse
time allowed is 60 seconds. To set the relay operation to toggle mode
allow the number of blinks to exceed 60. On the 61st blink the reader will
set the relay operation mode to Toggle and the reader will return to normal
mode. |