Home Up Feedback Contents Information                                                                            

Tag Simulator

Installation Tag Simulator

 

 

 

 

 

 

Contact Information

Telephone

+32 (0)3 722 91 60

Fax

+32 (0)3 722 91 66

Postal address

Zakstraat 104

9112 Sinaai

Belgium

Electronic mail

info@proxtech.com

 

 

Der PL500TS Tag Simulator ermöglicht das zulassen oder Sperren von Karten im Speicher vom PL500 System ohne dass die Präsenz der Originalkarte dabei erforderlich ist. Ein einziges Gerät kann auf verschiedene Installationen eingesetzt werden, wird allerdings nur zusammen mit der Masterkarte funktionieren.

Der Tag Simulator kann nicht verwendet werden um Zutritt zu bekommen.

Instructions of use of PL500TS

Power supply

The unit is powered by a PP3 9V battery. Undo the 2 screws at the back of the unit to gain access to the battery.

Setting Tag Number

To set the tag number to be deleted or added:

  1. Hold the On/Off button down.

  2. Use the RIGHT ARROW key to move the cursor to the digit to be changed.

  3. Use the UP ARROW key to change the number at the cursor.

  4. Repeat the above until all the digits of the number are correct.

  5. This number is stored in memory and the On/Off button may now be released

Deleting Tags

The MASTER tag must be used to put the PL500 into the Delete mode.

Once in Delete mode:

  1. RED lamp flashes

  2. Place the Tag Simulator close to the reader

  3. Hold down the On/Off button and check the displayed number

  4. Press the Send button

  5. The GREEN lamp will flash to verify that the selected number is deleted and then the RED lamp will continue flashing.

  6. Once the tag or a group of tags have been deleted, read the Master Tag to return to the RUN state.

Adding Tags

The MASTER tag must be used to put the PL500 into the Add mode.

Once in Add mode:

  1. GREEN lamp flashes

  2. Place the Tag Simulator close to the reader

  3. Hold down the On/Off button and check the displayed number

  4. Press the Send button

  5. The GREEN lamp will go steady and the relay will operate to verify that the selected number is added.  The GREEN lamp will then continue flashing.

  6. Once the tag or a group of tags have been added, read the Master Tag to return to the RUN state.

 

Send mail to info@proxtech.com with questions or comments about this web site.
Copyright © 2011 ProxTech International bvba