Installation instructions for OEM modules

125 kHz Module

Dimensions

     

 

Connections

 

PIN

 Function

 

GND

 GND ( 0 V )

 

+5V

 5 V +/- 0,5 V

 

NC

 Not Connected

 

Reset

 Reset

 

I/O 1

 Clock    Data0      RX

 

I/O 2

 Data     Data1      TX

 

I/O 3

 Not Connected

 

I/O 4

 Not Connected

 

I/O 5

 Not Connected

 

I/O 6

 Card Present    ( 0,5 sec active low )     max 20 mA TTL level

 Attention: Power supply must be well regulated, stable and free of noise.

13,56 MHz Module

Dimensions

   

               module dimensions                                          external antenna dimensions

 

Connections

Nr.
Pin
Function
Description

1

+UB

Power Supply

+5V DC

2

GND

Ground for Power Supply and Data

GND

3

Analog In

Analog Input

Do not connect

4

/Reset

Reset

Reader Reset when connected to GND

5

SCL

Digital In-/Output

Do not connect

6

SDA

Digital In-/Output

Do not connect

7

RXD/  B-

RS232 or RS485

RXD on TTL level or

optional on buffered RS 232 level

8

TXD/  A+

RS232 or RS485

TXD  on TTL level or

optional on buffered RS 232 level

9

I/O 1

Digital Output

Clock or Data 0

10

I/O 2

Digital Output

Data or Data 1

11

I/O 3

Digital In-/Output

Do not connect

12

I/O 4

Digital In-/Output

Do not connect

13

I/O 5

Digital In-/Output

Do not connect

14

I/O 6

Digital Output

Ca. 0,5 s active low  when tag detected

15

ANT1

Connection for external antenna

Connect to ANT1 of external antenna

16

ANT2

Connection for external antenna

Connect to ANT2 of external antenna

17

ANT3

Connection for external antenna

Connect to ANT3 of external antenna

18

ANT4

Connection for external antenna

Connect to ANT4 of external antenna

Attention: Power supply must be well regulated, stable and free of noise.

Note : For Legic modules, only antenna pins ANT1 & ANT2 need to be connected. Mifare modules have all 4 ANT pins connected.

 